Total Sulfur Analyzer / H2S Analyzer

HomeProductsApplicationsRepresentativesInvestor RelationsTrade ShowsEmploymentCustomer RelationsContact

h2s analyzer

 

The 903 H2S Analyzer Total Sulphur Analyzer

903 H2S Analyzer /
Total Sulphur Analyzer / H2S Measurement in Pipline Gas

 
903 H2S Analyzer
 

Galvanic’s 903 H2S Analyser is an online instrument designed to measure hydrogen sulphide (H2S) and / or total sulphur in natural gas and gaseous streams. A single analyser can be configured to monitor up to four (4) streams.

The instrument’s advanced digital colorimetric sensor measures the rate of darkening caused by the reaction of H2S on white tape impregnated with lead acetate in accordance with ASTM methods D4084-94, D4323-97 and D4468-95.

 

Benefits of the 903 H2S Analyzer /
Total Sulphur Analyzer

  • H2S specific measurement

  • Rapid response to both increasing or decreasing H2S levels

  • Low operation and maintenance costs

  • Superior precision and accuracy

  • Exceptional wide dynamic range

  • Unique over-range and multi-range measurement

  • Smooth, continuous operation from Galvanic TAPE ASSURANCE SYSTEM

  • Uninterrupted operation with dual-redundant AC and DC power supply

  • Remote diagnostics via serial or Ethernet communications

  • Self-diagnostics for troubleshooting

  • Variety of interface and connection options

  • CSA certified to meet hazardous area classifications

  • Analysis according to ASTM methods D4084-94, D4323-97 and D4468-95

Features of the 903 H2S Analyzer /
Total Sulphur Analyzer

Optical Tape Counter
Optical tape counter ensures exact spacing of stains as well as keeping track of tape consumption. Tape life of 5-14 weeks can be expected, depending on the application.

Advanced Digital Sensor at Measurement Point
AD converter is located at the sensor ensuring further accuracy by eliminating noise associated with transmitting analog signals.

Proprietary Humidifier
Unique humidifier design using permeable membrane reduces dead volume providing faster response time.

Explosion Proof Design
Certified to CSA (C/US) Class 1 Div. 1 or Class 1 Div. 2 electrical specifications for use in hazardous areas.

Indicator Lights
10 LED indicator lights provide quick status.

Dual Redundant Power Supply
All units capable of running on AC or DC power, or DC-backed AC power.

Total Sulphur (option)
Capable of measuring total sulphur with the addition of furnace.

Intrinsically Safe (IS) Keypad
16 button IS keypad allows user to configure and monitor unit without opening explosion proof enclosure.

Ethernet Communication
Allows units to connect into Ethernet-based networks providing remote operation and diagnostics capability.

128 x 64 LCD Screen
Large LCD screen on front of analyser provides information at a glance.

USB Port
Compatible with current PC s with no need for serial adapter.

Galvanic TAPE ASSURANCE SYSTEM
Galvanic’s ISO 9001-2001 quality assured tapes work together with a specially designed mechanical and optoelectronic system to ensure smooth and continuous operation.

Enhanced Data-Logging (512 kb)
Up to 10 months of data-logging provides user complete audit trail for troubleshooting and report generation.

User Friendly Software
Easy-to-use Windows-based PC software with graphical user interface for monitoring and analyser configuration. Can be used while PC is connected to front of analyser or remotely via serial link or Ethernet.

Fully Configurable System
Analyser can be customized to customer specific requirements. Configurable features include stream switching (on demand or timed sequence), automatic calibration, multi mode H2S - total sulphur measurement, reference and zero gas test, and multi-ranging.

Advanced Diagnostics
Feedback from microprocessors mounted on sensor block provide detailed diagnostics information such as sensor status, tape movement, tape length remaining, low sample pressure and temperature.

Field Programmable Memory
Easy to upgrade analyser firmware with PC via USB port or network connection.

Other Options

  • Custom Shelters: Galvanic offers complete analyser shelters from sun shades to complete buildings.

  • Hydrogen shut-off: Allows for automatic hydrogen shut off to total sulphur oven when analyser is monitoring H2S.

  • Additional Stream(s): Can analyse up to 4 streams.

  • Custom Sample Systems: Galvanic designs custom sample systems for customer’s specific requirements.

Applications of the 903 H2S Analyzer /
Total Sulphur Analyzer

Natural Gas / Shale Gas Processing

  • H2S Concentration at Plant Inlet

  • Product Quality at Plant Outlet

Natural Gas Pipelines

  • Product Quality at Custody Transfer Station

Synthetic Natural Gas (e.g. Coal Gasification)

  • Catalyst Protection / Product Quality

Gas Compression (LNG, GTL & NGL)

  • Catalyst Protection / Corrosion Control

  • Product Quality

Refining

  • H2S in Fuel Gas (EPA Reporting)

Petrochemical Feedstock

  • Catalyst Protection

  • Product Quality

Fuel Cell

  • PPB measurement of H2S and Sulphur

Emission Monitoring

  • Stack Analysis

 

Specifications of the 903 H2S Analyzer / Total Sulfur Analyzer

PDF Brochure of the 903 H2S Analyzer / Total Sulfur Analyzer

Application Sheet for the 903 H2S Analyzer





All information & content on this web site is © Galvanic Applied Sciences, 2000. All rights reserved.