AccuChrome™ GC

Btu & Hydrocarbon Analyzer

AccuChrome™ GC for Btu & C9+ Hydrocarbon

Btu + Hydrocarbon content for Natural Gas Processing and Custody Transfer.

AccuChrome is designed for critical monitoring in the harshest environments.

Whether you’re performing Btu and constituent analysis of natural gas for custody transfer, process optimization during natural gas fractionation, or 40 CFR 60 Subpart JA flare-gas emissions monitoring for regulatory compliance – you need precise, real-time measurements you can count on.

With auto calibration and validation capabilities to enable fully hands-off operation and the utmost in ease-of-operation, consistent, field-proven performance – and value, Galvanic’s AccuChrome analyzer can help you optimize your processes for better quality and lower costs. On rare occasions when there is a problem, it’s easy to address right then and there – the design enables ready access to all components, each of which are fully field-serviceable – reducing downtime and the need for costly module replacement.

Measurement Certainty

  • Accurate analysis with ±0.25 Btu per SCF
  • Rugged field-proven construction & full auto calibration & validation capabilities for full stand-alone operation
  • Airless heat sink oven & industry-leading, low-maintenance injection valves
  • Thermal-conductivity detector will not burn out with loss of carrier gas and can withstand corrosive H2S-
  • Designed for easy serviceability throughout
  • Multi-stream capability (up to 8 streams)
  • High-resolution local display & user-friendly software
  • 32 GB expansion storage capacity & complete audit trail of all results
  • Standard or customized reports, including location, technician, & comments

Available models

Choose the AccuChrome analyzer that’s right for your specific application needs

Model Analysis Configuration ADD neo-Pentane ADD H2S
AccuChrome C6+ Methane, Ethane, Propane, iso-Butane, n-Butane, iso-Pentane, n-Pentane, Hexanes Plus, Nitrogen, Carbon Dioxide X X
AccChrome C6+
Oxygen & Carbon Monoxide
Methane, Ethane, Propane, iso-Butane,n-Butane. iso-Pentane, n-Pentane, Hexanes Plus, Oxygen, Nitrogen, Carbon Dioxide, Carbon Monoxide X X
AccuChrome C7+ Methane, Ethane, Propane, iso-Butane, n-Butane, iso-Pentane, n-Pentane, Hexanes. Heptanes Plus, Nitrogen, Carbon Dioxide X X
AccChrome C7+
Oxygen & Carbon Monoxide
Methane, Ethane, Propane, iso-Butane, n-Butane, iso-Pentane, n-Pentane, Hexanes, Heptanes Plus, Oxygen, Nitrogen, Carbon Dioxide, Carbon Monoxide X X
AccChrome
for Hydrogen Only
Hydrogen Not Available Not Available

Look Closer

  • AccuChrome™ GC

    NEMS for C9 to C12

    The AccuChrome GC has a special add-on detection system called NEMS. NEMS works along with the traditional TCD system to more accurately measure heavier hydrocarbons up to C12.

  • AccuChrome™ GC

    Rugged Thermistor-Based Detector

    Less susceptible to fouling than micro-machined technology, the AccuChrome GC’s thermal-conductivity detector is able to withstand corrosive compounds such as H2S. Plus, Galvanic’s detector will not burn out on loss of carrier gas!

    Airless Heat-Sink Oven

    An airless heat sink oven maintains a constant temperature of columns, valves, and thermal-conductivity detector for reliable and accurate results. No external air source required!

  • AccuChrome™ GC

    Auto Calibration & Validation

    Calibration and validation is simple on the AccuChrome GC system. Auto validation lets you analyze the calibration standard without adjusting response factors or retention times. The AccuChrome GC supports two calibration standards for enhanced measurement of streams with widely varying hydrocarbon concentrations.

  • AccuChrome™ GC

    Durable Valves

    The chromatograph uses industry-leading valves. Tough and long lasting, the valves are rated for up to 1 million injections. Simple mechanical design makes it easy and inexpensive to service.

  • AccuChrome™ GC

    Micro-Packed Columns

    Galvanic manufactures its columns in house to assure the utmost in quality and consistency. This translates into results you can count on for the lifetime of the chromatograph.

  • AccuChrome™ GC

    External-Keypad-Driven Display

    An intrinsically safe external keypad provides full menu access for the high-resolution display, enabling at-a-glance status and results. View chromatograms, analysis results, previous calibration information, and alarms on the spot, without opening the enclosure – a feature unique to Galvanic systems.

  • AccuChrome™ GC

    Intuitive Operator Interface

    The AccuChrome GC Windows® software provides a powerful tool for operation, diagnostics and data handling. View and save chromatograms and analysis results, review or modify analysis settings, set up networking, generate reports, and control several other

    Easy Analyzer Networking & Data Communications

    Remote login and troubleshooting is easy via the AccuChrome GC Ethernet connection. The AccuChrome GC will support Ethernet Modbus TCP/IP and up to eight additional serial ports. Select a standard industry-compliant modbus list, generate customized modbus lists, or create and access multiple modbus lists via Scada. You can operate the TCP port as either master or slave; the AccuChrome GC supports up to 16 masters simultaneously.

  • AccuChrome™ GC

    Fast and Easy Reporting

    Produce printable reports of measured and calculated values based on GPA or ISO standards. Customize them to include location, technician name, and comments. The AccuChrome report generator makes it fast and easy.

Learn How AccuChromeGC Supports Your Gas Application