AccuSeries™

Wet Chemistry Analyzers

Rugged Multi-Parameter, Multi-Stream, Modular Wet Chemistry Analyzer

Galvanic’s AccuSeries are rugged on-line wet chemical analyzers. Multi-stream and multi-parameter methods offer customers an unbeatable price to performance ratio. The modular design, narrow footprint, and Class 1, Div. 2 certification simplifies installation and maintenance. Wetted parts are individually selected to provide the best compatibility with customer’s samples. Analyses are configurable to any standard method (EPA, ISO, ASTM) to ensure they match up with the lab. Advanced sample conditioning (digestion, extraction, dilution) expands testing capabilities. Remote analyzer control is achieved with a standard remote desktop user interface. Systems are completely programmable with diagnostics and alarms to alert users of adverse process conditions.

AccuSeries Liquid Analyzers offer the following techniques:

  •       Colorimetric
  •       Color Titration
  •       Potentiometric Titration
  •       Ion Selective Electrode
  •       Direct Measurement

AccuSeries systems can be configured to accommodate special custom analysis methods. To speak with a Galvanic applications expert, call +1.978.848.2701, or email info@galvanic.com

Download Specifications PDF

Talk to a Galvanic Applications Expert

Features

Robust Modular Design
  • Rated -20 to 60C for Long Life under Harsh Operating Conditions
Remote Analyzer Control
  • Available Via Modbus, Ethernet, 4-20 mA 
Narrow 16” Width
  • Small Footprint Simplifies Installation
± 2 ppb Accuracy
  • For 0 to 100 ppb Calibration Ranges
User-Defined Methods
  • Match the Lab & Avoid interferences
Hazardous Area Rated
  • Meets Div. 2 & Zone 2 without a Purge
Custom Wetted Parts
  • Maximum Resistance to Handle Samples Up to 70C
Wide ¼” Tubing
  • Handles High Turbidity & Upset Conditions
Internal Fast-Loop:
  • Ensures Representative Sample Every Analysis
Fast ROI
  • Multi-Parameter & Multi-Stream (Up to 6)
Programmable “Robotic Chemist”
  • Fully Automatic Sampling, Calibration, Cleaning

Selected Industries & Applications

Biofuel
  • Pretreatment
  • Digestion
  • Biofuels
Boiler & Cooling Tower
  • Microbiological Control
  • Scaling Prevention
  • Corrosion Monitoring
  • Coagulation & Flocculation
  • Leak Detection
Chemical
  • Mining
  • Fertilizer & Pesticide
  • Personal Care
  • Polymer production
  • Paints & Inks
  • Textile
  • Pharmaceutical
Chlor-Alkali
  • Brine Purification
  • Chlorine & Bleach Production
  • EDC
  • Caustic Scrubber
Edible Oils Processing
  • Solvent Extraction
  • Degumming
  • Neutralization
  • Bleaching
  • Deodorization
Food & Beverage
  • Dairy
  • Sugar Refining
  • Meat Processing
  • Bottled Water, Juices & Soft Drinks
  • Beer, Wine, Spirits
  • Clean-In-Place (CIP) Systems
Hydraulic Fracturing
  • Injection Water & Produced Water
  • Working Tanks
Municipal Water & Wastewater
  • Collection System
  • Coagulation & Flocculation
  • Nutrient Removal
  • Oxidation & Filtration
  • Aeration Tank
  • Disinfection
  • Effluent & Distribution
Petrochemical & Natural Gas Processing
  • Crude Distillation Unit
  • De-Salter
  • Amine & Caustic Scrubber
  • Alkylation & Polymerization
  • Petroleum Products
  • Stripped Sour Water
Power Plant
  • Nuclear & Thermal
  • Water-Steam Circuit
  • Flue Gas Scrubber
  • Steam Turbine & Turbine Oil
Pulp & Paper
  • Kraft Bleaching
  • Causticizing
  • Black, White, Green Liquors
Semiconductor
  • Etching & Plating
  • Photoresist Stripping
Steam Assisted Gravity Drainage (SAGD)
  • Make Up & Produced Water
  • Hot Lime Softening
  • Weak Acid Cation (WAC) Ion Exchange
Surface Finishing
  • Plating
  • Pickling Baths
  • Solar
  • Aerospace

Available models

Choose the AccuSeries liquid analyzer that’s right for your specific application needs

Model Description Selected Analyte/Parameters
AccuColor AccuColor performs color titrations and colorimetric analyses. The color produced by the chemical reaction of reagents is directly proportional to the parameter being measured. The system’s dual-wavelength and auto-blank feature compensate for background color and turbidity. The sensor has excellent chemical resistance and is cleaned between analyses to prevent optics fouling. The optical path length is customized to allow for both low and high concentration detection using a multi-point calibration. • Hardness in Brine
• Mercaptans in Jet Fuel
• Hydrazine in Boiler Feed
• Manganese in Municipal Water
AccuSense AccuSense performs potentiometric titrations and direct ISE measurements. Titrations involve a known standard solution mixing with sample until an equilibrium is reached proportional to the concentration of the parameter being measured. ISE measurements are performed using an ionic strength adjusting buffer to identify specific ion concentrations. Low range measurements can be performed using a standard known addition calibration standard. • ABC Analysis in Pulp Liquor
• Acid Gas for Amine Sweetening
• H2S in Waste Water
• Caustic/Carbonate in Scrubber
Methods Acid Gas Loading; Acid Number; Acetic Acid; Boric Acid; Citric Acid; Cyanuric Acid; Hydrochloric Acid; Hydrofluoric Acid; Lactic Acid; Organic Acid; Nitric Acid; Phosphoric Acid; Sulfuric Acid; Acidity; Alkalinity; Aluminium; Amine; Ammonia; Ammonium; barium; Base Number; Bicarbonate; Boron; Bromide; Bromine; Cadmium; Calcium; Carbon Dioxide; Carbonate; Caustic; Chlorate; Chloride; Chlorine; Chlorite; Chromium; Cobalt; Color; Copper; Cyanide; Free Fatty Acids; Fluoride; Fluoroborate; Formol Number; FOS-TAC; Hardness; Hydrazine; Hydrogen Peroxide; Hydrogen SUlfide; Hypochlorite; Iodide; Iodine; Iron; Lead; Magnesium; Mercaptans; Mercaptides; Mesityl Oxide; Molybdate; Nickel; Nitrate; Nitrite; Perchlorate; Persulfate; Phenol; Phosphate; Phosphorus; Potassium; Silica; Silver; Sodium; Sodium Chloride; Sulfate; Sulfide; Sulfite; Sulfur Dioxide; Surfactants; T.M.A.H.; Tert-Butyl-Catechol; Thiocyante; Thiosulfate; Thiourea; Urea; Zinc

Download Specifications PDF

Talk to a Galvanic Applications Expert

Look Closer

  • Unique Sample-Capture System

    Our patented sample-capture technique provides the simplest and most reliable method of capturing a reproducible volume of sample.

  • AccuSeries™

    Menu-Driven Display Guides User Through Set-Up & Operation

    The AccuSeries system is simple to operate by even novice users with minimal training.

  • AccuSeries™

    Wide-bore Sample-Inlet Tubing

    Minimizes blockages, allowing even high-turbidity samples to be handled readily.

Download the AccuSeries Brochure