HomeProductsApplicationsRepresentativesInvestor RelationsTrade ShowsEmploymentCustomer RelationsContact


 



Tytronics

COLORMETRIC, TITRIMETRIC, ISE, AND SPECTROPHOTOMETRIC ANALYZER

Galvanic Applied Sciences USA manufactures the complete product line of Tytronics online wet chemical and gas analyzers. The Tytronics products include the Sentinel and FPA series of On-line Analyzers. These analyzers use “state of the art” technology to perform colorimetric, titrimetric, ISE, and spectrophotometric analyses. These analyzers can be configured to perform many EPA and ASTM wet chemical methods, as well as many standard methods. The Sentinel and FPA analyzers use a modular design that can be configured to meet the specific requirements of the customer's application.

Sentinel Analyzers

 

Multi-stream chemical analyzers capable of determining A (Aluminum) to Z (Zinc)

The Sentinel Analyzer is capable of both process chemical analysis and the monitoring of potable water and wastewater. This instrument can analyze up to six streams for the same chemical species, at different concentration ranges.

Click here for the complete brochure on the Tytronics Sentinel (PDF - 1.44 MB)



FPA Analyzers

 

Single stream process analyzers

The FPA Series Analyzers are designed specifically for process applications in the chemical, petrochemical, and oil refining industries. The FPA Series includes analyzers with flow-through cells for UV/Visible spectrophotometric measurements. These analyzers have an intrinsically safe user interface keypad, which makes them well suited for applications located in hazardous areas.


Tytronics analyzers features:
  • Patented sample capture system

  • Multiple alarm functions

  • Multi-stream analysis (Sentinel)

  • Dual wavelength (optical analyzers)

  • Intrinsically safe user interface (FPA)

  • Auto calibration

  • Low & high concentration analyses

  • Auto cleaning

  • Superior detector technologies

  • Modular, reliable & rugged design

Tytronics applications include:
  • Acidity

  • Ammonia

  • Hardness

  • Nitrate

  • Chlorine

  • Sulfide

  • Chromium

  • Caustic & carbonate

  • Aromatic hydrocarbons in water

  • Alkalinity

  • Amines

  • Iron

  • Silica

  • Copper

  • Manganese

  • Oil in water

  • And many others



FPA 300/400/800 Series

 

FPA 300™ Process Potentiometric Titrator
pH/ORP/ISE TITRATIONS

The Tytronics™ FPA 300 series delivers simple, reliable and highly cost-effective on-line titration. Acid-base, redox and other analyses are typical applications in a wide variety of industries, including; chemicals, petrochemicals, textiles, metal finishing and pulp & paper.

FPA 400™ Process Colorimetric Titrator
pH INDICATOR/NON-AQUEOUS/COMPEXOMETRICTITRATIONS

The Tytronics™ FPA 400™ series is an extension of the proven FPA 300™, adding applications for titrating to a color endpoint. Colorimetric titration offers on-line analytical capability at trace levels in applications such as monitoring plant effluent and municipal water, and environmental analysis in general.

FPA 800™ PROCESS COLORIMETER
COMPLEXOMETRIC METHODS

reaction cell is used both to capture and to analyze the sample. A dipping colorimetric probe is mounted in the reaction cell to measure the absorbance of the resulting solution.

The reaction cell contains no moving parts, except for the magnetic stirrer, and is available in various materials (an acrylic cell is standard) All sample and reagent lines are 1/4”. Mixing is accomplished through the use of a magnetic Teflon™ coated stir bar. Fiberoptics are used to transmit light to and from the reaction cell. The light source is a tungsten filament which provides a continuum in the visible and NIR region. The fiberoptics bundle of the return path is bifurcated to facilitate the dual wavelength operation.


FPA 300™ SERIES APPLICATIONS

  • ABC Test in Paper Pulping

  • Acids

  • Boric Acid

  • Alkalinity

  • Caustic and

  • Carbonate

  • Chlorine/Hypochlorite

  • Cyanide

  • Copper

  • Hydrochloric Acid in Pickling Solutions

  • Peroxide

  • Sulfide in Sour-Gas Treatment

  • Sulfuric Acid in Pickling Solutions

Tytonics Colorimetric Titrator - FPA 400™ SERIES APPLICATIONS

  • Hardness

  • Sulfite

  • Acid Value of Organic Solvents

  • Acidity or Alkalinityof Fuels

  • Bromine number & index

  • Mercaptans in fuels

Click here for the complete brochure on Tytronics FPA 300/400/800 Series (PDF - 0.5 MB)



FPA 1000/1100 Series

 

PROCESS SPECTROPHOTOMETERS
FIELD PROGRAMMABLE ANALYZERS /
PROCESS UV SPECTROPHOTOMETERS

The FPA 1000/1100 series uses a design that separates the electronics from the measurement cell. Fiberoptics are used to transmit light to and from the measurement cell.

The use of fiberoptics simplifies installation and reduces maintenance costs. The measurement cell mounts directly into the process stream which avoids the need for a separate sampling system in many applications. There are no electrical connections at the cell, avoiding explosion-proof requirements at the sample point. The cell requires no optical alignment at time of installation or after routine maintenance. This further aids rapid installation and greatly eases maintenance by plant personnel.

A single beam, dual wavelength, optical configuration corrects for window coating, sample turbidity or light intensity changes from interfering with the instrument’s results. Automatic calibration insures instrument accuracy.

The electronics are microprocessor-controlled with full on-board diagnostics. With these features process engineers can now choose an on-line spectrophotometer which is simple to install and gives reproducible and accurate result over a wide range of process conditions. By design, these instruments are virtually maintenance-free.


FPA 1000 Series (VIS/NIR) Applications:

  • Copper

  • Nickel

  • Cobalt

  • Hazen Color

  • Saybolt Color

  • Water in Organics

  • Organic Solvents

FPA 1100 Series (UV) applications:

  • Chlorine

  • Hypochlorite

  • Benzene

  • Aromatics in Water

  • Nitrate

  • Dowtherms

  • Formaldehyde

  • Phenols

  • UV254 TOC/COD

  • ...and more...


Click here for the complete brochure on FPA 1000/1100 SERIES (PDF - 0.450 MB)

 

FPA 4000/4100 Series


The FPA 4000/4100 is an online spectrophotometer capable of measuring the concentration of many analytes in process liquid or gas streams. The FPA 4000/4100 uses well established spectrophotometric techniques to perform the measurement. In general, energy from a source lamp is transmitted to a measurement cell via a multi-standed fiber optics bundle. The sample continuously flows through the cell, where the analyte of interest will absorb energy from the light source. The energy that passes through the cell is then transmitted to a set of photodetectors via a bifurcated fiber optics bundle. The amount of energy absorbed by the sample is proportional to the concentration of the analyte in accordance with Beer’s Law.

The FPA uses a single beam, dual wavelength design. The energy that passes through the measurement cell is split so that it is directed to two photodetectors, one for reference and one for measure. Each photodetector is equipped with a bandpass filter such that only a single wavelength can be measured. The measure wavelength is selected in a region of the spectrum where the analyte of interest is known to absorb strongly. The reference wavelength is selected in a region of the spectrum where the analyte of interest does not absorb. The dual wavelength design compensates the measurement for turbidity of the sample, optical window coating and loss of light intensity over time.

Benefits

  • No reagents required for the analysis.

  • Rapid response.

  • Long lamp life.

  • Dual wavelength operation minimizes the effect of turbidity in liquid samples.

  • Measures in true absorbance and hence response is linear with concentration.

  • Automatic calibration.

  • Automatic washing of cell when required.

  • Large separation of the photonic and control units thus facilitating the installation of the analyser.

  • Automatic temperature and pressure correction for gaseous measurements.

  • Measurement cells may be heated using an oven or by steam jacketing.

  • Cell may be for by-pass line or in-line.

Applications

  • Oil in water

  • Aromatics in solution

  • Oil in boiler condensate

  • COD (Chemical Oxygen Demand)

  • Leakage of heat exchange fluids (eg, Dowtherm and Therminol)

  • Chlorine in water

  • Chlorine in vent gases

  • Hydrogen sulphide in gas

  • Sulphur dioxide in gas

  • Nitrogen oxides in gas

  • Para-tert-butylcatechol in butadiene

  • Phosgene in process streams

  • Chlorine in phosgene

  • Hypochorite for deodourising control

  • Hazen colour of water and solvents

  • Saybolt colour of fuels and oils

  • ASTM colour

  • Copper in concentrate and plating solutions

  • Nickel and Cobalt in electro-wining solutions

  • Permanganate in water

  • Nitrate in water

  • Nitrobodies in Pink water plants

  • % Water in organic solvents

Click here for the complete brochure on FPA 4000/4100 SERIES (PDF - 912K)



Click here for the Application Sheet (PDF - 43K)





All information & content on this web site is © Galvanic Applied Sciences, 2000. All rights reserved.